PMI Energy Management Products

The SP1000 monitors and records over 60 measurements within the electrical system. The collected data can be stored in 5 minute intervals for over 16 months. We are the first company to be able to monitor, record and quantify true kw/kwh savings at affordable prices.

The system functions dynamically by making thousands of decisions per minute based on what the SP1000 is reading through its external and internal current transmitters. The system will than address harmonics, voltage imbalance, and power factor within the facility. Cable losses within a facility are minimized. The savings realized by the SP1000 are contingent on the overall facilities efficiency, energy rates, and demand charges.

The SP1000 system has the ability to switch on and off millions of times without burning our Patented Switch. Our method of switching consumes only 20% of the energy normally used by other types of switches.

Our monitoring application platform (SPIDER) provides a dashboard where real time results can be observed. Charts and tools to generate reports, delivering the ability to see things such as motor deterioration, so you can be proactive and make a change instead of reactive.

Below is our list of currently available SP1000 models.

SP1000A - 120/208V, 10 KVAR rated, and Neutral Line required

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capacitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000A 4 Normal 120 / 208 DELTA 180 0 10 YES 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000A2 - 120/240V, 11 KVAR rated

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000A2 4 Hi Leg 120 / 240 DELTA 180 0 11 NO 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000B - 120/208V, 18 KVAR Rated, and Neutral Line required

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000B 6 Normal 120 / 208 DELTA 360 0 18 YES 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000B2 - 120/240V, 18 KVAR Rated

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000B2 6 Hi Leg 120 / 240 DELTA 360 0 18 NO 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000C - 220/380V, 10 KVAR Rated, and Neutral Line Required

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000C 4 Normal 220 / 380 WYE 180 0 10 YES 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000D - 220/380V, 20 KVAR Rated, and Neutral Line Required

Model Name Number of Banks Panel Type Voltage1 phase/3 phase SP1000Bank Format Capacitor (uF)Per Phase Fixed CapicitorAmount Per Phase Total KVARRating Neutral LineRequired Line Frequency
SP1000D 6 Normal 220 / 380 WYE 360 0 20 YES 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000D2 - 220/380V, 20 KVAR Rated

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000D2 6 Normal 220 / 380 WYE 360 60 20 NO 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000E - 277/480V, 30 KVAR Rated, Neutral Line Required

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000E 6 Normal 277 / 480 WYE 320 120 30 YES 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000E2 - 277/480V, 24 KVAR Rated, Neutral Line Required

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000E2 6 Normal 277 / 480 WYE 240 0 24 YES 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000E3 - 277/480V, 24 KVAR Rated

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000E3 6 Normal 277 / 480 WYE 240 40 24 NO 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000E7 - 277/480V, 28 KVAR Rated, Neutral Line Required

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000E7 7 Normal 277 / 480 WYE 280 0 28 YES 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage

SP1000E8 - 277/480V, 28 KVAR Rated

Model Name Number of Banks Panel Type Voltage
1 phase/3 phase
SP1000
Bank Format
Capacitor (uF)
Per Phase
Fixed Capicitor
Amount Per Phase
Total KVAR
Rating
Neutral Line
Required
Line Frequency
SP1000E8 7 Normal 277 / 480 WYE 280 40 28 NO 60
* Voltage: Model May Use a Lower Voltage Panel, but KVAR Rating Has To Be Modified To Correspond To The Applied Voltage